Comparing the environmental impact of using various energy sources in family house heating systems

Henryk Manteuffel



Marcin Bukowski




Аннотация

Environmental impacts of using various sources of energy in heating a family house with 180 m2 of floor surface were compared by means of the SimaPro computer programme and attached to its databases, describing the environmental impacts of using typical materials and technologies. The set of compared heat energy sources comprised a ground loop, a heat pump, a liquid gas combustion furnace, an earth gas combustion furnace, a coal combustion furnace, a straw combustion furnace, a wood combustion furnace and an electric stove. After normalisation (which meant recalculating the impacts into their shares in the average impact of the kind, experienced by an average European in a year), weighting (which meant attaching arbitrary weights to three aggregate impact categories according to a methodology Eco-indicator 99 E/E) and aggregating the results into so called eco-points the wood combustion furnace turned out to have the greatest impact. It was followed by a coal burning furnace, an electric stove and an oil burning furnace. The heat pump had the smallest impact. A big impact of the wood and other biomass burning furnaces was due to a high emission of CO presumed in the used database, which can be disputed.

Ключевые слова:

family house heating, environmental impact, SimaPro application, Eco-indicator 99

Adamczyk, A. (2004). Ekologia wyrobów. Warsaw: Polskie Wydawnictwo Ekonomiczne.
  Google Scholar

Czaplicka, K.; Wachowicz, J.; Bojarska-Kraus, M. (2001). Ekowskaźnik 99 jako narzędzie do ekologicznego projektowania wyrobów z tworzyw sztucznych. Kompozyty (Composites) 1.
  Google Scholar

Introduction to LCA with SimaPro (2008). PRe product ecology consultants. Amsterdam.
  Google Scholar

Laskowski, P. (2006). W czym palić? Murator 9: 178-189.
  Google Scholar

Laskowski, P. (2007). Jaki kocioł wybrać? Murator 1: 132-138.
  Google Scholar

Laskowski, P. (2008). Ile za ciepło? Murator 10.
  Google Scholar

Małkowska, I. (2006). Kocioł na miarę. Budujemy dom 7-8: 78-111.
  Google Scholar

Manteuffel Szoege, H.; Olesik, L. (2008). Technology Dependent House Heating Costs. In: Towards a holistic approach based on science and humanity. 6th Biennial International Workshop Advances in Energy Studies. Graz University of Technology. Graz.
  Google Scholar

PN-EN ISO 14040 lipiec 2009 (2009). Zarządzanie środowiskowe. Ocena cyklu życia. Zasady i struktura . Warsaw: Polski Komitet Normalizacyjny.
  Google Scholar

Wach, A. (2002). Metoda oceny cyklu życia (LCA) jako podstawa komputerowo wspomaganej oceny wyrobu. In: II Krajowa Konferencja Naukowo-Techniczna „Ekologia w elektronice”. Warsaw: Przemysłowy Instytut Elektroniki.
  Google Scholar


Опубликован
2020-12-11

##plugins.themes.libcom.cytowania##

Manteuffel, H., & Bukowski, M. (2020). Comparing the environmental impact of using various energy sources in family house heating systems. Economic and Environmental Studies, 13(1 (25), 49–60. извлечено от https://czasopisma.uni.opole.pl/index.php/ees/article/view/3001

Authors

Henryk Manteuffel 

Authors

Marcin Bukowski 

Statistics

Скачивания

Данные скачивания пока недоступны.